会议专题

Numerical Study of the Accessorial Loop with a Micro-pump and Ejector for the Capillary Pumped Loop

An accessorial loop with a micro-pump and ejector is applied into the Capillary Pumped Loop (CPL), and a 3-D model is developed to investigate the operation performance of the ejector. The numerical results show that the mass flux can be enhanced with an accessorial loop. However, a sub-cooler is necessary to locate between the outlet of the ejector and the inlet of the evaporator to condense the mixed fluid into liquid.

capillary pumped loop micro-pump ejector cavitation erosion ejecting coefficient

Su Kalin Wan Zhongmin Liu Jing Rong Jun Yang Huafeng

Department of Physics Hunan Institute of Science and Technology Yueyang, China School of Energy and Power Engineering Huazhong University of Science and Technology Wuhan, China

国际会议

The 2010 International Conference on Computer Application and System Modeling(2010计算机应用与系统建模国际会议 ICCASM 2010)

太原

英文

67-69

2010-10-22(万方平台首次上网日期,不代表论文的发表时间)