会议专题

Influence of Split-feed Influent on Process Performance of Anaerobic Baffled Reactor

The study was on the process performance of Splitfeed influent which was used to treat simulated tannery wastewater and compared with Single influent in an anaerobic baffled reactor that had six compartments under the conditions of HRT 24h and COD 3000~3500mg/L during the experiment. When the influent ratio was separately 6:3:1 and 5:3:2 in the first、third and fifth compartment, the variety of sludge、pH、COD、VFA were investigated. The results showed the average removal rate of COD in single influent was 86.4%, and influent ratio of 5:3:2 and 6:3:1 were seperately 89.8% and 88.2%, which were all better than single influent.

anaerobic Baffled Reactor split-feed influent microorganism activity

DING Shaolan QIN Ning DONG Lingxiao

College of Resource & Environment, Shaanxi University of Science&TechnoLogy, Xi’an, 710021, P.R.China

国际会议

The 12th International Wool Research Conference(第十二届国际羊毛会议12th IWRC)

上海

英文

631-635

2010-10-19(万方平台首次上网日期,不代表论文的发表时间)