Study on the Performance of Perfluorooctanesulfonamide Compounds on the Different Gas Chromatographic Columns
The gas chromatographic behaviors of two neutral hydrophobic perfluorooctanesulfonamide compounds, such as perfluorooctanesulfonamide (PFOSA) and N-ethyl perfluorooctanesulfonamide (N-EtPFOSA) were studied on DB-1701 and DB-5ms column. The analysis results revealed that low detection limit, good peak shape and good separability of two perfluorooctanesulfonamide compounds could be obtained on DB-1701 column.
perfluorooctanesulfonamide compounds chromatographic column gas chromatography/mass spectrometry
WANG Gaixia LIN Danli WANG Yuhuan WANG Jianqing
College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P Research Center for Analysis and Measurement, Donghua University, Shanghai 201620, P.R.China
国际会议
The 12th International Wool Research Conference(第十二届国际羊毛会议12th IWRC)
上海
英文
797-801
2010-10-19(万方平台首次上网日期,不代表论文的发表时间)