Calibration Technique for the Lens Distortion of CCD Optical Target

According to the measurement principle of the CCD optical target, the measurement accuracys influence made from lens distortion has been analyzed and a method of lens distortion correction that is suitable for CCD optical target has been propose. Using 10mm black and white stripes interval as the standard template image that has been compared and processed under the different object distance condition, the distortion correction function has been established by image processing and MATLAB curve fitting, indicates the deviation between the field of view and imaging pixels. The method is simple, precise, and operable so on. The measurement accuracy of CCD optical target has been improved significantly after the lens distortion correction by using this method.

CCD target Radial distortion camera calibration lens distortion calibration

Zemin Wang Zhiyong Lei Junchai Gao Xiaona Ding Yaning Wang

School of Electronic Information Engineering Xian Technological University Xian, Shaanxi, China Vehicle Department Unit 66267 of PLA Shijiazhuang, Hebei, China

国际会议

2010 International Conference on Information,Networking and Automation(2010 IEEE信息网络与自动化国际会议 ICINA 2010)

昆明

英文

373-376

2010-10-17(万方平台首次上网日期,不代表论文的发表时间)