会议专题

EXPERIMENTAL STUDIES ON THE CHARACTERISTIC OF MORTISE-TENON JOINT IN HISTORIC TIMBER BUILDINGS

The typical mortise-tenon joints in historic timber buildings were analyzed in mechanics. The low cyclic reversed loading tests were carried out. The semirigid characteristic of the joggle joint and the change rules of stiffness degradation were obtained. The moment-deflection angle hysteretic loops were tested. By imitating the state of mortise-tenon joint with the varied stiffness element,the relation between the varied stiffness and the relative flexibility was found. It is shown that the stiffness change of the mortise-tenon joint is nonlinear from 0.3062 to 23.6054 with the change of load. It may provide information,suggestions and theoretical base for seismic research,protection and maintenance of historic timber buildings.

Timber structure Mortise-tenon joint Semi-rigid Stiffness degradation

Hong-Peng Ge Kai Wu Jian-Yang Xue Jian-Fang Bai Kan Yao

School of civil engineering,Xian University of Architecture and Technology,Xian 710055,P.R. China School of civil engineering,Xian University of Architecture and Technology,Xian 710055,P.R. China School of civil engineering,Xian University of Architecture and Technology,Xian 710055,P.R. China School of Civil Engineering,Shijiazhuang Railway Institute,Shijiazhuang 050043,P.R.China Unit 95022 of Chinese Peoples Liberation Army,Shantou,Guangdong 515800,P.R. China

国际会议

The Eleventh International Symposium on Structural Engineering(第十一届结构工程国际研讨会)

广州

英文

587-594