CRITICAL TEMPERATURES DETERMINATION FOR MONOLAYER CABLE NET GLASS CURTAIN WALL UNDER FIRE CONDITIONS
Monolayer cable net glass curtain wall becomes the developing trend of large scale curtain wall structure system in China. However,corresponding fire-resisting research work has been lagged. Its important and necessary to give a simple method to get fire-resisting critical temperature of this kind of structure. An FEA software ANSYS was employed to establish Series of numerical calculations models. The principle for determining critical temperature was discussed deeply. The critical temperature table including different spans,grid dimensions and cable diameters is given. It could help designers for getting critical temperature rapidly.
Monolayer cable net Glass curtain wall Critical temperature Fire FEA
Yin Bai Shi-Feng Cheng Yong-Jiu Shi Yuan-Qing Wang
School of Transportation Science and Engineering,Beijing University of Aeronautics and Astronautics, Beijing Institute of Architectural Design,Beijing 100045,P.R.China Department of Civil Engineering,Key Laboratory of Structural Engineering and Vibration of China Educ
国际会议
The Eleventh International Symposium on Structural Engineering(第十一届结构工程国际研讨会)
广州
英文
2231-2234
2010-12-01(万方平台首次上网日期,不代表论文的发表时间)