Flow Rate Measurement of Oil/Gas/Water Three-Phase Flow with V-Cone Flow Meter
Mass flow rate is an important parameter of oil/gas/water three-phase flow, most multi-phase flow meters are based on the measurement of total mass flow rate and phase fraction. As the Reynolds number of three-phase flow grows to a certain number, the oil and water phase are considered as a homogenous mixture with a mixed density. In this case, oil/gas/water three-phase flow could be measured as gas/liquid two-phase flow. A V-cone flow meter with beta ratio of 0.65 is used to make the mass flow rate measurement, the calibration experiment is carried out with oil/water flow, the effect of oil proportion and the mixture Reynolds number on the discharge coefficient of V-cone flow meter is discussed. Comparison of four typical differential pressure correlations is put forward under experiment condition. Lin correlation best behaved in the experiment and error analysis is done based on it. The experiment result shows the mass flow rate of oil/gas/water flow could be measured by V-cone flow meter efficiently and the experiment error is acceptable.
Oil/Gas/Water Three-phase Flow Differential Pressure Model V-cone Flow Meter
F.S.Zhang F.Dong
Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation,Tianjin University, Tianjin 300072, China
国际会议
西安
英文
178-182
2009-07-11(万方平台首次上网日期,不代表论文的发表时间)