Experimental Research on the Performance of Exhaust Steam Reclaim Device With a Swirling Flow Vane

This paper experimentally studied the performance of exhaust steam reclaim device with a swirling flow vane at different inlet water pressures, temperatures, different inlet steam pressures and different distances between the throat and spout. The results indicated that the injection coefficient decreased as the inlet water pressure and temperature increased, respectively. There is a best distance between the throat and spout which makes the injection coefficient reached to its maximal value at the same experimental pressure and temperature, and the value equals to 130mm in our experimental system. The resistance coefficient has a minimum value which makes the device have the highest outlet water pressure. Compared with the device without a swirling flow vane, it improves the heating performance for higher injection coefficient and exergy efficiency.