会议专题

Effect of Slug Flow on CO2 Corrosion

Multiphase flow induced CO2 corrosion has resulted in serious losses in oil and gas production. In this paper, gas-liquid two-phase vertical upward slug flow has been analyzed from aspects containing flow structure, hydrodynamic characteristics, mass transfer characteristics and their effects on pipe wall and corrosion product film, and it is found that slug flow has a distinct effect on transports of corroding species to and of corrosion products from the wall, momentum interchange between fluid and wall and the formation and damage of corrosion product film. In addition, the transports of corrosive species and corrosion product are also an important step in CO2 corrosion process. It is assumed that the slug flow induced CO2 corrosion of pipeline is dependent on the non-linear coupling of the characteristics including the shear stress, the normal stress, the mass transfer coefficient, and the electrochemical reaction.

Slug flow Hydrodynamic characteristics Mass transfer characteristics Corrosion product film Carbon dioxide corrosion

Y.B.Zhang K.Yan D.F.Che

State Key Laboratory of Multiphase Flow in Power Engineering, Xian Jiaotong University, Xian,China

国际会议

The 6th International Symposium on Multiphase Flow,Heat Mass Transfer and Energy Conversion(第六届多相流、传热传质与能源转化国际学术会议)

西安

英文

403-409

2009-07-11(万方平台首次上网日期,不代表论文的发表时间)