Very High Cycle Fatigue Behavior and Thermographic Analysis of High Strength Steel
Very high cycle fatigue behavior of high strength steel, were investigated using ultrasonic fatigue testing equipment at 20 kHz up to 109cycles. S-N curves at room temperature with different stress ratio (R=0.01 and R=0.1) was determined. The experimental results show that fatigue strength decrease with increasing number of cycles between 105 and 109. SEM examination of fracture surface reveals that fatigue damage was governed by the formation of cracks, and subsurface crack initiation was in the very long life range. The results shown that the portions of life attributed to subsurface crack initiation between 107 and 109 cycles are 99%.
Very high cycle fatigue High strength steel Fish eye Infrared imaging
SHAO Chuang Cloude BATHIAS Danièle WAGNER TAO Hua
School of Mechatronic Engineering, Northwestern Polytechnical University, Xi’an 710072, China LEEE, LEEE, Université PARIS X, Ville d’avray, 92410, France School of Mechatronic Engineering, Northwestern Polytechnical University, Xi’an 710072, China
国际会议
沈阳
英文
948-951
2010-07-28(万方平台首次上网日期,不代表论文的发表时间)