DC Bus Voltage Feedforward Analysis and Regulation for Interconnected Power Converters with CPL

Power electronics based distributed power systems are more and more used in different situations. In these systems, with tight regulation, the load converters may exhibit constant power load (CPL) behavior with negative impedance, and the system stability would be degraded severely. In this paper, an active method using DC bus voltage feedforward is proposed to overcome these problems. A typical DC distributed power system is employed to analysis the design method by using small signal linearization around the operating point. Furthermore, least mean square (LMS) based adaptation is used to enhance the design. The simulation results show the validation of the proposed analysis and design method.

Power converters Distributed power system Feedforward Adaptive Impedance

Jiang You Lijun Yu Fanrong Meng Bin Fu Jianwen Cui

College of AutomationHarbin Engineering UniversityHarbin,Heilongjiang,China College of Automation Harbin Engineering University Harbin,Heilongjiang,China

国际会议

2010 IEEE信息与自动化国际会议(ICIA 2010)

哈尔滨

英文

1-4

2010-06-20(万方平台首次上网日期,不代表论文的发表时间)