会议专题

One Curve-Fit Method for the Evaluation of the Total Distortion of Sinusoidal Signal

With the requirement of measurement and the development of electronic technology, the index of distortion measurement technique has a larger increase. How to improve the measurement accuracy and extend the frequency domain is becoming more and more important. The current method of sine waveform distortion measurement is reviewed and the total distortion measurement technique for the sine waveform, which is based on curve-fit method, is discussed in this paper. Aiming to solve the problem that it is difficult to obtain the parameters in curve-fit method, a new method and its complete procedure are developed by using the Hilbert-Huang transform (HHT) and the ergodicity method to obtain the parameters of base wave curve and to evaluate the total distortion. Unlike classical three- or four-parameter sine-wave fitting procedure, this method avoids selecting initial value of the parameters and working out the nonlinear equations. The feasibility and effectiveness of this method and procedure were verified through a group of simulation results, with a signal at the frequency of 1 MHz.

Distortion Evaluation Sine wave Hilbert-Huang transform Ergodicity

Hui Wang Yunjian Ge Zhengshi Liu Huanjin Liu Liang Xu

Institute of Intelligent Machines Chinese Academy of Sciences Hefei,Anhui Province,China Institute of Sound & Vibration Research Hefei University of Technology Hefei,Anhui Province,China

国际会议

2010 IEEE信息与自动化国际会议(ICIA 2010)

哈尔滨

英文

1-6

2010-06-20(万方平台首次上网日期,不代表论文的发表时间)