Technical Implementation of Electromagnetic Flowmeter in Partially Filled Pipes
This paper designs the electromagnetic flowmeter in partially filled pipes (EMF-PF), which sensor sets four electrodes. One pair of the electrodes is set on the pipe bottom as the signal injection electrodes that inject the AC pulses used to determine liquid fill height. One pair of long-arc electrodes is set on the pipe wall as the measurement electrodes. The measurement electrodes alternate duties, sensing both the flow and fill height signals. Both the flow and fill height raw signals are disposed in different time period by the same signal processing channels. Experiment result shows that the designed EMF-PF can achieve the flow measurement in partially filled pipes, and the measurement accuracy of this EMF-PF meets the actual requirements.
partially filled pipes flow measurement EMF-PF
Wei Kaixia Hao Guoshen Zhu Xinchen
Dept. of Computer,Xuzhou Normal University,Xuzhou,221116 ,China
国际会议
厦门
英文
144-148
2010-05-22(万方平台首次上网日期,不代表论文的发表时间)