会议专题

Research of Quartz Crystal Series Resonant Parameter Measurement Using Direct Transmission Method

On the basis of researching quartz crystal measurement standards and methods based on the direct transmission method, quartz crystal, an electrical parameter model of a π-network and its effect to the measurement accuracy of electrical parameters of quartz crystal have been analyzed, and a measurement technique of quartz crystal series resonant frequency parameters has been researched. Based on the research, the measurement system has been designed. The results of measurement experiments show that when the measurement system is in the 200MHz frequency range, the measurement error of the series resonant frequency is less than 2ppm, and the measurement error of the series resonant resistance is less than 10% (or 2Ω).

quartz crystal measurement resonant frequency direct transmission method

Li Dong Wang Yanlin Liu Guili Wang Xiaofei Liu Gang

Key Laboratory of Modern Measurement & Control Technology,Ministry of Education. Beijing 100192 China Optoelectronic Information and Communication Engineering College,Beijing Information Science and Technology University Beijing 100192 China

国际会议

The Third International Symposium on Test Automation & Instrumentation(第三届国际自动化测试与仪器仪表学术会议 2010 ISTAI)

厦门

英文