会议专题

Study on Oil Sampling Method of Power-shift Steering Transmission

Oil sampling and oil sample pretreatment has an important impact on the results of oil analysis. This paper analyzes oil analysis condition monitoring principle, introduces an integrated transmission devices working principle, structural characteristics of hydraulic lubrication system, and seven aspects in oil analysis condition monitoring such as sampling tool, sampling location, sampling cycle, reference oil sample, sampling condition, sampling record, sampler, It is validated that the oil sample pretreatment method is suitable for the transmission device. It has been found that the sampling method can ensure the quality of oil sampling and can ensure proper oil analysis condition monitoring.

Transmission Device Oil Analysis Condition Monitoring

Wang Liyong Xu Xiaoli Wu Guoxin

School of Mechanical& Electrical engineering,Beijing Information Science & Technology University,Bei Key Laboratory of Modern Measurement & Control Technology (Ministry of Education),Beijing Informatio

国际会议

The Third International Symposium on Test Automation & Instrumentation(第三届国际自动化测试与仪器仪表学术会议 2010 ISTAI)

厦门

英文

1266-1270

2010-05-22(万方平台首次上网日期,不代表论文的发表时间)