Numerical computation and analysis of temperature field of hydraulic motor pump

Finite element models of the flow field and temperature field of the axial piston hydraulic motor pump has been established based on the software ANSYS/FLOTRAN, numerical simulation of the flow field coupling with numerical simulation of temperature field has been carried out and the distribution and analysis indicates that flowing fluid inside the motor pump stator can take most of the heat produced by the motor pump outside, keep the temperature of the motor pump within normal value 40 ℃.The heat conductivity of the stator winding have greater influence on the distribution of the temperature field. The research work provides reliable data for the design and optimization of the cooling channel.

Hydraulic motor pump Temperature field Cooling channel Stator

Dajie Zhang Dianrong Gao Youjie Wang Xianghui Lu

Hebei Province Key Laboratory of Heavy Machinery Fluid Power Transmission and Control, Yanshan University, Qinhuangdao, China

国际会议

The Seventh International Conference on Fluid Power Transmission and Control(第七届流体传动与控制国际学术会议 ICFP 2009))

杭州