Research on PV module structure based on Fault detection
As to detecting the occurrence of Hot Spot, this paper presents a new type of photovoltaic (PV) arrays connection: CTCT structure (complex-total-cross-tied array). In the array of CTCT-type PV cells, by adding a certain number of current sensors and comparing the current, we can find the location of PV cells that have Hot Spot. This paper derives a formula to demonstrate the relationship between the total number of solar panels in parallel, the resolution and the total number of current sensors. We can detect the precise location of PV cells that have Hot Spot by using current sensors as few as possible.
Hot Spot PV Array Fault Detection CTCT structure
Yanli Liu Bingfeng Li Ze Cheng
School of Electrical Engineering and Automation, Tianjin University, Tianjin, 300072
国际会议
The 22nd China Control and Decision Conference(2010年中国控制与决策会议)
徐州
英文
3891-3895
2010-05-26(万方平台首次上网日期,不代表论文的发表时间)