Research of three-loop Control Method Of PV Grid-connected Inverter
The traditional control method for PV grid-connected inverter is two closed loop, if this control method is used for PV grid-connected system, the indication of slow response or increased troubles of system design which is caused by instability of switching frequency. This paper presents a three-loop control to overcome such problems, voltage external loop, current middle loop and frequency inner loop are included this method can solve above-mentioned disadvantages and make the output current THD of grid-connected inverter is a little value. Through building a mathematic model for the PV grid-connected system, the MATLAB/SIMULINK simulation results show that the presented control method is feasible and effective.
Three-loop Control Hysteresis Band PV grid-connected Inverter
Yi Lingzhi Li Ming Liu Xiang Deng Dong Yao Zhezhi
College Of Information Engineering, Xiangtan University, Xiangtan Hunan 410005,China
国际会议
The 22nd China Control and Decision Conference(2010年中国控制与决策会议)
徐州
英文
4281-4285
2010-05-26(万方平台首次上网日期,不代表论文的发表时间)