Research on Self-regulation of Delay Arming Time of MR Fluid Fuze

With the development of science and technology, its performance of delay arming device has been continually improved. However, bore premature, premature detonation, failure to fire and other grave accidents have still often happened in recent years. The reason is that delay arming device prematurely rescinds fuse safety mechanism or its fail of delaying arming mechanism. It has been widely focused on how to improve its safety and reliability of delay arming device at home and abroad, but there have only been few researches on its self-regulation of delay arming time. Based on its principle of MR fluid damp controlling technology and its yield stress of MR fluid will be changed with its changes of magnetic field strength, design and simulation of magnetic circuit for MR fluid fuze has been done in this paper. And this model among input current of coil, discharge aperture and time of discharge has been obtained by test and some useful results are made by numerical simulation. The experimental results prove that its delay arming time of MR fuze meets the design requirements and indicate that input current of coil has an obvious effect on discharge time.

Delay arming time Magnetorheological fluid fuze Self-regulation Magnetic field

Hongsheng Hu Jiong Wang Bo Liu

School of Mechanical and Electrical Engineering, Jiaxing University, Jiaxing, 314001, China School o School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Chi

国际会议

The 22nd China Control and Decision Conference(2010年中国控制与决策会议)

徐州

英文

285-289

2010-05-26(万方平台首次上网日期,不代表论文的发表时间)