The Study to Pressure and Flow Measurement for Hydraulic System on Basis of Non- inserting Technology
The non-inserting measurement of the pressure and flow and the technology to the hydraulic system for fault diagnosis are reviewed. A new measurement method using pipe distortion to measure the pressure and flow of the fluid in the pipe based on non-inserting technology was proposed. The feasibility corresponding measuring deformation of the pipeline by strain method was proved. The guidance for the location of the clamps in the pipe has been given. Experiments were analyzed. The dynamic pressure in hydraulic pipe can be measured by strain method was proved. The flow was calculated by the dynamic pressure using the pipeline dynamic model.
Non- plug-in Fluid power Flow rate Pressure Measurement
An Ji Sun Yuqing Zhang Hongpeng Zhang Yindong
Marine Eng. College, Dalian Maritime Univ., Dalian, 116026 P.C. China11000
国际会议
The 22nd China Control and Decision Conference(2010年中国控制与决策会议)
徐州
英文
696-700
2010-05-26(万方平台首次上网日期,不代表论文的发表时间)