会议专题

Experimental Research on Vibration Response Characteristics of Air Spring with Auxiliary Chamber

Based on Firestone 1T15M-2 diaphragm type air spring, the experiment system of air spring with auxiliary chamber was established. The influences of orifice diameter and auxiliary chamber volume to vibration response of air spring with auxiliary chamber were studied by the means of experiment. The experiment results show that, with the increase of orifice diameter, the stiffness of air spring with auxiliary chamber decreases, and the damp of system increases first, and when d=5mm, the damp of system reaches to maximum, after that the damp of system begins to decrease with the further increase of orifice diameter. Enlarging auxiliary chambers volume can reduce the stiffness of the system of air spring with auxiliary chamber, and at the same time, enlarging auxiliary chambers volume also can increase the damp of system. But when the ratio of auxiliary chamber and air spring is greater than 2, changing the volume of auxiliary chamber would have little effect on the stiffness and damping.

Air spring Auxiliary chamber Vibration characteristics Experiment

Wang Jiasheng Zhu Sihong

Qingdao Agricultural University, Qingdao, Shandong, 266109,China College of Engineering, Nanjing Agricultural University, Nanjing, 210031, Jiangsu, China

国际会议

2010 International Conference on Measuring Technology and Mechatronics Automation(ICMTMA 2010)(2010年检测技术与机电自动化国际会议)

长沙

英文

1307-1310