Study on Design the Stop Pipe Diameter of Packaging Viscous Fluid
The distribution of the speed and shear stress in viscous fluid with the laminar flow in the pipe were anal lyzed in this paper, then, the flow rate was calculated. Moreover, the stop pipe diameter was designed by calculating the balance of shear stress of viscous fluid in the pipe and the gravity of filling fluid. Analysis have The conclusions : stop pipe diameter of viscous fluid is proportional to viscosity and the square root of pipe length, and is inversely proportional to the acceleration of gravity and the square root of the filling factor.
viscous fluid diameter speed stress flow rate
Yang Fu-xin Wang Sheng-ze
College of Mechanical Engineering Donghua University, 200051 Shanghai, China College of Mechanical Engineering Donghua University, 200051 Shanghai,China
国际会议
长沙
英文
2279-2281
2009-10-10(万方平台首次上网日期,不代表论文的发表时间)