Study on Characteristics of Variable Voltage and Variable Frequency Motor with Broken Rotor Bars

The induction motor is commonly operated at variable voltage and variable frequency state at present. The broken rotor bars fault is one common fault in the operation state. The electromagnetic and thermal characteristics of induction motor in broken rotor bar condition are very important fault characteristics. The electromagnetic field of induction motor at fault is analyzed by finite element method. Based on the results above, the temperature distribution and temperature rise of induction motor is analyzed in different broken rotor bar and typical area with maximal temperature rise is investigated too. At last, fault characteristics at broken rotor bar are obtained as a criterion for fault diagnosis.

induction motor magnetical charateristics temperature rise

Taozhen Dai Maoyong Cao Likui Wang Jing Shi

Department of Information and Electrical Engineering Shandong University of Science and Technology Q Applied Superconductivity Center Huazhong University of Science and Technology Wuhan, China

国际会议

2009 International Conference on Applied Superconductivity and Electromagnetic Devices(应用超导与电磁装置技术国际会议 ASEME 2009)

成都

英文

48-51