The Experimental Research on the Algorithms for Calculating Power Fault Current In Security and Stability Control Device
The accurate calculation of fault current is an important step in power fault detection, it is very important for the security and stability control devices which play a significant role during the safe and stable operation of power system. This article explains the experimental research on the algorithms such as half-wave integration, root-mean-square method and FFT algorithm. After comparison and analysis, conclusions are obtained. Finally, FFT algorithm is chosen as the algorithm for calculating fault current of security and stability control devices based on the experimental results which may be useful to other measurement, control and protection devices.
fault current calculation FFT algorithm halfwave integration inter-phase faults non-periodic DC component power system RMS root-mean-square method security and stability control device the safe and stable operation
Qiuhua Li Xiaoqing Xuan Jinghai Song Xueming Li.
State Grid Electric Power Research Institute, Nanjing, China
国际会议
The International Conference on Electrical Engineering 2009(2009 电机工程国际会议)
沈阳
英文
1-4
2009-07-05(万方平台首次上网日期,不代表论文的发表时间)