Reliability Analysis of 100MN Multi Way Die Forging Water Presss Computer Control System
This paper analyzed the reliability of 100MN multi way die forging water presss computer control system by means of fault tree, and established the model of the fault tree of the control system, then calculated the mean time between fault( MTBF) of the system; to deal with the less reliability part ,this paper afford improving means by changing the system structure and enhance redundant of key subsystem to ensure water press running safely and reliably.
ZHOU Yucai LI Jieming
College of Energy and power Engineering, Changsha University of Science & Technology,Changsha 410076, P.R. China
国际会议
长沙
英文
1111-1115
2008-10-20(万方平台首次上网日期,不代表论文的发表时间)