会议专题

An Ezperimental Study on Green Water-storing Roofs Removal Efficiency of Pollutants in Rainwater Runoff

This article makes an experimental study on the quality of common roof rainwater and the rainwater treated by the green water-storing roof. The findings are as follows: the urban green water-storing roof has a high removal efficiency of SS, COD, TN and TP in roof rainwater runoff. To be specific, the removal rate of SS can be up to 80% to 90%; COD, 50% to 70%; TN, 50% to 70%.TP, 40% to 70%. After the pollutants are removed by the green water-storing roof, the roof rainwater can meet the quality standard of Urban Wastewater Reuse: Urban Miscellaneous Water Quality(GB/T 18920-2002).

Rainwater runoff green water-storing roof removal rate utilization of rainwater resources

Saijun Zhou Bozhi Ren Renjian Deng

College of Civil Engineering, Hunan University of Science and Technology, Xiangtan Hunan, 411201

国际会议

2009 Beijing International Environmental Technology Conference(2009北京国际环境技术会议暨第五届“中、德、波环境技术研讨会)

北京

英文

287-293