会议专题

Treatment of heavy metal-containing industrial wastewater by the multistage rotating biological contactor

The ability of a three-stage rotating biological contactor (RBC) to treat industrial wastewater with copper and zinc was investigated. The optimuM operation parameters of the whole system for the maximum COD removal is HRT 15h and rotating speed 9 rpm. The system successfully removed the zinc and copper with the removal efficiency 90% and 71% respectively. Analysis of the contribution of each stage of RBC indicated that COD and metal removal were not uniform, with first stage showing a much higher removal capacity than the second and third stages.

rotating biological contactor (RBC) copper zinc industrial wastewater

Songyan Qin Tianshun Liu Jian Qin Fuyong Deng Lu Chen

School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin, 3 Tianjin Municipal Engineering Design and Research Institute, Tianjin, 300051 Chemical Industry and Ecology Institute, North University of China, Taiyuan, 030051

国际会议

2009 Beijing International Environmental Technology Conference(2009北京国际环境技术会议暨第五届“中、德、波环境技术研讨会)

北京

英文

294-299

2009-10-16(万方平台首次上网日期,不代表论文的发表时间)