Flow-Saturated Resistant Control Simulation of Load-Sensing System

Aiming at solving the problem that the load-sensing system can not distribute flow proportionally under condition of flow-saturated, a control method, also Flow-Saturated Resistant Control, is proposed based on pressure difference control strategy and a comparison analysis with respect to the hydraulic system is carried out with the help of co-simulation of AMESim and Simulink. The simulation results showed that the load-sensing system improved by flow- saturated resistant control can realize proportional flow distribution that is independent of load.
Load-sensing Pressure compensation Flow-satu-ation Flow distribution
Wang Xin Cao Baozhong Song Xiaoguang Gao Shunde Duan Baogang Wang Huimin
School of Mechanical Engineer, Dalian University of Technology, Dalian 116024, P. R.China School of Mechanical Engineer, Dalian University of Technology, Dalian 116024, P. R. China Dalian YILIYA Construction Machinery Co., Ltd., Dalian 116025, P.R.China School of Mechanical Engineer, Dalian University of Technology, Dalian 116024,P. R. China School of Mechanical Engineer, Dalian University of Technology,Dalian 116024, P. R. China Dalian YILIYA Construction Machinery Co.,Ltd.,Dalian 116025, P. R. China
国际会议
长春
英文
59-62
2009-08-21(万方平台首次上网日期,不代表论文的发表时间)