会议专题

Research on Multi-channel smoke screen infrared transmittance measurement

A multi-channel scan measurement instrument designed for characterizing the infrared obscuring performance of smoke screen at the wavelength of 10.6 μm is developed. It offers 1 to 5 sensors for multi points real time measurements of infrared transmissivity in the field. Data transmission is accomplished by wireless communication. The maximum detection range of the instrument is 500 meters with measurement accuracy better than ± 5%.

smoke screen infrared radiation transmissivity wireless communication

Lixin Gao Qi Wang Luyuan Xiong Jian Bao Jinzu Wang

Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences Hefei , China

国际会议

2009 2nd IEEE International Conference on Computer Science and Information Technology(第二届计算机科学与信息技术国际会议 ICCSIT2009)

北京

英文

1899-1902

2009-08-08(万方平台首次上网日期,不代表论文的发表时间)