SIMULTANEOUS DETERMINATION OF HEXENURONIC ACID AND KAPPA NUMBER OF HIGH-YIELD KRAFT PULPS USING PAS-FTIR
A rapid scan photoacoustic Fourier transform infrared (PAS-FTIR) method was developed for the determination of Kappa number and hexeneuronic acid (hexA) content in kraft pulps. A partial-least-squares (PLS) model was established based on spectral data collected at different mirror velocities. The robustness of the model was statistically evaluated. The outcomes indicate that the PLS model can be used to predict Kappa number and hexA content in kraft pulps with a high degree of accuracy provided that the scan depth is sufficient to be representative of the samples.
PAS-FTIR hzeneuronic acid kappa number kraft pulp
Vinh Q. Dang Nishi K. Bhardwaj Kien L. Nguyen
Australian Pulp and Paper Institute Department of Chemical Engineering Monash University, Australia
国际会议
广州
英文
816-820
2006-11-08(万方平台首次上网日期,不代表论文的发表时间)