Study on UPF Harmonic Current Detection Method Based on DSP
Unity power factor (UPF) harmonic current detection method applied to active power filter (APF) is presented in this paper. The intention of this method is to make nonlinear loads and active power filter in parallel to be an equivalent resistance. So after compensation, source current is sinusoidal, and has the same shape of source voltage. Meanwhile, there is no harmonic in source current, and the power factor becomes one. The mathematic model of proposed method and the optimum project for equivalent low pass filter in measurement are presented. Finally, the proposed detection method applied to a shunt active power filter experimental prototype based on DSP TMS320F2812 is developed. Simulation and experiment results indicate the method is simple and easy to implement, and can obtain the real-time calculation of harmonic current exactly.
H J Zhao Y F Pang Z M Qiu M Chen
Northwestern Polytechnical University, Xian 710072,China Xian University of Technology, Xian 710048,China
国际会议
第四届仪器科学与技术国际会议( 4th International Symposium on Instrumentation and Science and Tcchnology)
哈尔滨
英文
1327-1331
2006-08-08(万方平台首次上网日期,不代表论文的发表时间)