会议专题

Studies on the Standard and Test Procedure of Compactness of Gravelly Clay in the Core Wall of Rockfill Dam

Through the analysis of the test procedure of compactness of compacted gravelly clay which has been used in the core wall of rock-fill dam,and the designation of the excel table for the automatic calculation of compactness of compacted gravelly clay,it can be concluded that the compactness of compacted gravelly clay can be calculated accurately and quickly by applying the Excel table and Hilfs method of small particles (<20 mm) of compacted gravelly clay.Moreover,some suggestions to the test standard of compactness of compacted gravelly clay are put forward.

rock-fill dam with core wall clay mizing with gravel Compactness,the standard of test

Zhao Chuan Wu Min Shen Siyuan Li Xiaolian Gu Tao

Huaneng Lancang River Hydro power Co.,Ltd.,Kunming 650214,China

国际会议

The 1st International Symposium on Rockfill Dams(第一届堆石坝国际研讨会)

成都

英文

455-461

2009-10-18(万方平台首次上网日期,不代表论文的发表时间)