Ezperimental research on anionic reverse flotation of hematite with a flotation column
An experimental research on magnetic concentrate of a hematite using the anionic reverse flotation technology in the flotation column was conducted. Through systematic studies in the lab, the optimal technological and operational conditions had been obtained as follows: the circulation pressure of 0.055 MPa, the feeding quantity of 160 g/min, the collector dosage of 800 g/t and the starch dosage of 900 g/t. The results show that the iron concentrate with grade of 67.37% can be achieved according to the flow sheet of one roughing and one scavenging under the optimal conditions, and also reflects the advantages of excellent selectivity and high recovery. The application of cyclonic static micro-bubble flotation column in hematite reverse flotation provides a new approach for hematite reverse flotation in China.
flotation column hematite anionic reverse flotation
Li Lin Liu Jiong-tian Wang Yong-tian Cao Yi-jun Zhang Hai-jun Yu He-sheng
School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221 Schulich School of Engineering University of Calgary, Calgary, Alberta,T2N 1N4, Canada
国际会议
The 6th International Conference on Mining Science & Technology ICMST 2009(第六届国际矿业科学技术大会)
徐州
英文
1-8
2009-10-18(万方平台首次上网日期,不代表论文的发表时间)