会议专题

Identification of Parameters in a High-frequency Current Transducer Using for Partial Discharge Measurements

In order to obtain partial discharge (PD) measurements under impulse voltage,a PD measuring probe based on a current transducer was constructed.In this paper,the transfer function of the current transducer was proposed,and bode plot simulated the effect of changing some of variables,then by selecting magnetic cores and optimizing chief parameters,a PD measuring probe has both wide bandwidth and high sensitivity was gained.Calibration results and measuring PD of needle-plate model under impulse voltage demonstrated that the developed current transducer can reproduce the actual waveform of the discharge current accurately.

current transducer partial discharge measurement transfer function impulse voltage.

Xuefeng Zhao Zhenquan Sun Zhifeng Guo Yanming Li

School of Electrical Engineering,Xian Jiaotong University,Xian 710049,China

国际会议

2009 9th International Conference on Electronic Measurement & Instruments(第九届电子测量与仪器国际会议 ICEMI2009)

北京

英文

413-416

2009-08-16(万方平台首次上网日期,不代表论文的发表时间)