Azial High-temperature RF SQUID Gradiometer System for Geomagnetic Prospecting
In order to implement the geomagnetic prospecting in unshielded environment,an axial high-temperature radio frequency superconducting quantum interference device (RF SQUID) gradiometer system operating in liquid nitrogen at 77K is proposed in the paper. The gradiometer consists of two RF SQUID magnetometers,each with sensitivity better than 30 fT/Hz1/2. The gradiometer baseline is adjustable from 6 cm to 10 cm. The SQUID electronics we designed is automated and the working points are adjusted by the integrated microcontroller. The system maintains continuously two RF SQUID magnetometers in the fluxlocking condition. According to a long-term experiment,it is indicated that the gradiometer system developed by us demonstrated a good performance in the application of geomagnetic prospecting.
RF SQUID gradiometer SQUID electronics geomagnetic prospecting.
Jing Zhao Jun Wang Guangda Liu
College of Instrumentation and Electrical Engineering,Jilin University,No.938 Ximinzhu Street,Changchun,130061,China
国际会议
2009 9th International Conference on Electronic Measurement & Instruments(第九届电子测量与仪器国际会议 ICEMI2009)
北京
英文
704-707
2009-08-16(万方平台首次上网日期,不代表论文的发表时间)