会议专题

System Design and Ezperimental Research on Tip Clearance Measurement of Areo-Engines by Digital Radiograph

For aero-engine tip clearance measurement requirements under different running state,this paper presents a high-energy X-ray digital radiography inspection system based on the linear accelerator and scintillation screen coupled cooled CCD camera. The system uses a high conversion efficiency,highresolution scintillation screen combine highsensitivity CCD cameras for the digital X-ray transparent image acquisition,and analysis of tip clearance and other changes in the internal structure to get the dynamic measurement of displacement through image processing. In order to verify the feasibility of the system design,experimental research is presented and discussed.

tip clearance z-ray radiography scintillation screen CCD camera.

Yongshun Xiao Zhiqiang Chen Li Zhang

Department of Engineering Physics of Tsinghua University Key Laboratory of Particle & Radiation Imaging,Ministry of Education Beijing 100084 China

国际会议

2009 9th International Conference on Electronic Measurement & Instruments(第九届电子测量与仪器国际会议 ICEMI2009)

北京

英文

1348-1351

2009-08-16(万方平台首次上网日期,不代表论文的发表时间)