会议专题

Ezperiment Study On Control Methods Of Common Rail Pressure By Entering Flow

In this paper,the control methods of common rail pressure by regulating rate of entering flow are studied. The control circuit and solenoid valve are Trial-manufactured The pressure of common rail controlled by Trial-manufactured solenoid valve are tested in test-bed. The results show that The opening time of Trial-manufactured solenoid valve is 1.1ms,and its closing time is 0.9ms. it can satisfy the requires of common rail system.

zommon rail rail pressure control entering flow control.

Shijie An Guangyao Ouyang Jingqiu Zhang Kun Yang

College of Naval Architecture and Power,Naval University of Engineering Wuhan 430033,China

国际会议

2009 9th International Conference on Electronic Measurement & Instruments(第九届电子测量与仪器国际会议 ICEMI2009)

北京

英文

2934-2937

2009-08-16(万方平台首次上网日期,不代表论文的发表时间)