Study on Fault Diagnosis of Gear Wearing Based on Non-stationary Acoustic Signal
Because of the restriction of self-propelled gun full-scale test, and because the traditional vibration test cant be used for non-contact, nondisassembly and nondestructive test. A method that utilizes the non-stationary acoustic signal for gearbox fault diagnosis was introduced. In order to process the non-stationary signals such as speed up signals effectively, the order tracking technique were presented. Combined the cepstrum analysis to conquer the disadvantage of traditional FFT when processing non-stationary signal. Compared to the vibration signals, the gearbox gear wearing fault experiment and data analyzing showed its feasibility and superiority.
Fault diagnosis gear wearing, non-stationary acoustic signal order tracking analysis cepstrum.
Guang Tian Xinjie Shao Qiao Ma Jinhua Liu
Ordnance Engineering College,Shijiazhuang,050003,China
国际会议
2009 9th International Conference on Electronic Measurement & Instruments(第九届电子测量与仪器国际会议 ICEMI2009)
北京
英文
4011-4014
2009-08-16(万方平台首次上网日期,不代表论文的发表时间)