Analog Circuit Fault Diagnosis Using Higher Order Cumulants
An approach to analog circuit fault diagnosis using higher order cumulants (HOC) is described in this paper. Our system used a harmonic signal to excite the circuit under test (CUT), and then the response was putted into a Butterworth filter bank. For each subband filter, the output sequence was analyzed by higher order cumulants. Skewness, a 1-D slice of 3 (rd) -order cumulant was used in the system as fault feature. The simulation results showed that this was an effective method for analog circuit diagnosis. The fault trend was distinguished also by this method. Moreover, the fault coverage was improved.
analog circuit fault diagnosis filter bank higher order cumulant skewness.
Taiwen Yuan Yongle Xie Guangju Chen
School of Mechatronics Engineering,University of Electronic Science and Technology of China Chengdu School of Automation Engineering,University of Electronic Science and Technology of China Chengdu 61
国际会议
2009 9th International Conference on Electronic Measurement & Instruments(第九届电子测量与仪器国际会议 ICEMI2009)
北京
英文
4279-7282
2009-08-16(万方平台首次上网日期,不代表论文的发表时间)