Impact of RTD on NH3-N Removal Efficiency by Three-Phase Internal Fluidized Bed
This paper conducted the effects of residence time distribution (RTD) on NH3-N removal efficiency by three-phase internal fluidized bed. Pulse testing was applied under different flow patterns, using NaCl as the tracer. Then number of tank-in-series was determined to approach1 and the reactor could be considered as a Continuous Stirred-Tank Reactor (CSTR). Different HRT was compared and it concluded that as HRT =1.5 h, volume utilization ratio reached the highest level, and the maximum removal efficiency of NH3-N (>90%) was obtained. These results validated the good reliability of the RTD testing, and provided the basic data and knowledge for determination the reactor size and scale-up ratio.
three-phase internal fluidized bed RTD NH3-N removal
JIANG Nan WANG Heli
School of Water resources and Environment,China University of Geosciences,Beijing 100083,China
国际会议
2009 International Symposium on Environmental Science and Technology(2009环境科学与技术国际会议)
上海
英文
1711-1713
2009-06-02(万方平台首次上网日期,不代表论文的发表时间)