会议专题

EXPERIMENTAL STUDY ON THE BOND BEHAVIOR BETWEEN BFRP TENDON AND CONCRETE

As a new-style material, basalt fiber reinforced polymer tendon (BFRP tendon) as a substitute for steel bars used in concrete structure is an effective method which could resolve the problem of concrete durability aroused by the corrupt of steel bars. For the mechanical performance of BFRP tendon and the bond behavior between BFRP tendon and concrete were not clear, ribbed and deformed BFRP tendon of diameter 8 mm tensile test and standard pullout test were made and compared with steel bars of diameter 8 and 10 mm standard pullout test. The test result shows that the BFRP tendon has high tensile strength and low elastic modulus compared to steel bar; the bond strength between BFRP tendon and concrete is similar to steel bars with the same diameter and presents good bond performance; and the bond strength ratio of the two different bars is 1.04, so the bond strength relative coefficient of BFRP tendon could considered as 1.0.

BFRP tendon tensile strength elastic modulus pullout test bond slip

Wen-Jie Ge Ji-Wen Zhang Yong-Ming Tu Jian-Pin Lv

Key Laboratory of Concrete and Prestressed Concrete Structure of Ministry of Education,Southeast Uni Key Laboratory of Concrete and Prestressed Concrete Structure of Ministry of Education, Southeast Un Key Laboratory of Concrete and Prestressed Concrete Structure of Ministry of Education, Southeast Un

国际会议

2009年土木工程结构创新与可持续发展国际会议(The International Symposium on Innovation & Sustainability of Structures in Civil Engineering)

广州

英文

115-119

2009-11-28(万方平台首次上网日期,不代表论文的发表时间)