OVERSTRENGTH FACTOR STUDY OF STEEL PLATE SHEAR WALL WITH SEMI-RIGID CONNECTED STEEL FRAMES
To study the overstrength factor of the steel plate shear wall with semi-rigid connected steel frame, a series of the structures with different spans and stories are designed according to Chinese seismic codes in this paper. Nonlinear analysis of the designed structures is done through static pushover (SPO) method and a synthetically method, which combine incremental dynamic analysis (EDA) and static pushover (SPO) together. Performance point for calculation of overstrength factor is defined during the analysis. From the study a conservative overstrength factor of the steel plate shear wall with semi-rigid connected steel frames, which designed with Chinese seismic codes, is presented as 4.0.The influence of different spans and stories for overstrength factor is discussed in this paper also.
overstrength factor incremental dynamic analysis static pushover steel plate shear wall with semi-rigid connected steel Frames
Gao-Bo Liu Qiang Gu Long Qin Kuan-Feng Zhang
School of Civil Engineering, Xian University of Architecture & Technology,Xian 710055, P.R. China Dept. of Civil Engineering, USTS, Suzhou 215011, P.R. China Dept. of Civil Engineering, Engineering College of Armed Police Force, Xian 710086, P.R. China Pipe Branch of Xian Second Municipal Engineering Co., Xian 710075, P.R. China