Statistical Results on the EMP Conductive Susceptibility of a Serial Network Measurement and Control Device
The EMP conductive susceptibility of a measurement and control device used in automatic management system is studied by experimental test.Two EMP waveforms with different rise time are applied to the devices.Responses of the EUT are measured and compared.The sensitivity thresholds of EUT are analyzed by statistical method.Results show the EMP with fast leading edge tends to cause more serious interference when its amplitude remains the same as the EMP with slow leading edge.
electromagnetic Pulse (EMP) conductive susceptibility failure rate (FR) coupling
Shi Li-hua Yu Yang Zhou Ying-hui Zhou Bi-hua
Nanjing Engineering Institute,210007,Nanjing,China
国际会议
Asia-Pacific Conference on Environmental Electromagnetics CEEM2009(第五届亚太环境电磁学学术会议)
西安
英文
13-16
2009-09-16(万方平台首次上网日期,不代表论文的发表时间)