Comparison of the Measurement Method for Surface Transfer Impedance in Frequency-Domain and Time-Domain
aimed to acquire the screening efficiency of the shielded coaxial cable a time-domain measurement method is proposed and a test system based on the triaxial test fixture is designed.By using FFT, time-domain test result can be transformed in to frequency-domain.Comparison shows they fit well with each other.The proposed time-domain test method provides a more straight way to observe the screen efficiency of cables under pulsed fields.
transfer impedance time-domain measurement triazial method
Zhou Ying-Hui Shi Li-Hua Zhou Bi-Hua Gao Cheng Chen Bin
Nanjing Engineering Institute,210007,Nanjing,China
国际会议
Asia-Pacific Conference on Environmental Electromagnetics CEEM2009(第五届亚太环境电磁学学术会议)
西安
英文
54-57
2009-09-16(万方平台首次上网日期,不代表论文的发表时间)