New Technique for SE Measurement of Small Enclosures within Reverberation Chamber
For various applications, there is a growing need to determine the shielding effectiveness (SE) of physically small (but electrically large) enclosures or cavities.In this paper, a new measurement technique for SE of small enclosures is presented.This new technique is based on the statistical methods and multi-points measurement.The work is intended to provide further refinement in the consideration of shielding effectiveness in a complex electromagnetic environment.
reverberation chamber small enclosure shielding effectiveness testing method
CHENG Er-wei WANG Qing-guo QU Zhao-ming JIA Rui
The National Key Lab of EM & EM Protection,Mechanical Engineering College,Shijiazhuang 050003,China
国际会议
Asia-Pacific Conference on Environmental Electromagnetics CEEM2009(第五届亚太环境电磁学学术会议)
西安
英文
301-304
2009-09-16(万方平台首次上网日期,不代表论文的发表时间)