Standard Resistor Calibration Method in Measurement of Noise Source Impedance Using Dual-probe Approach
This paper presents the standard resistor sub-fitting calibration method in measurement of electromagnetic interference (EMI) noise impedance by using dual-current-probe approach.By this method, a more accurate noise source impedance and theoretical model are obtained.Experiments show this method is effective in noise impedance, and suitable for filter design.
noise source impedance resistor calibration dual-current-probe approach
Zhao Bo Zhao Min Feng Zhiming Yao Min
College of Automation Engineering,Nanjing University of Aeronautics & Astronautics,Nanjing,P.R.China College of Automation Engineering,Nanjing University of Aeronautics & Astronautics,Nanjing,P.R.China EMC Department,Jiangsu Institute of Metrology,Nanjing,P.R.China