Analysis and Implementation of Voltage Stress in Performance Degradation Test
PARD (Periodic and Random Deviation) of controllable power is important to the study on performance degradation of electronic equipment under voltage stress with different PARD.Taking switching power as an example in this paper the PARD signal is analyzed in time domain and frequency domain.We find that it is closer to real situation when peak-peak value (Vp-p) and characteristic frequency are selected as the main characteristic parameters of DC power PARD.At the same time the hardware of voltage with different PARD is implemented using the method of AC superposed DC.
Performance degradation Power PARD AC superposed DC
Zhang Fang Cai Jinyan Zhu Yanhui
Optics and Electronics Department Ordnance Engineering College Shijiazhuang,China The military representative section stayed in 5413 factory Shijiazhuang,China
国际会议
2009 8th International Conference on Reliability,Maintainability and Safety(第八届中国国际可靠性、维修性、安全性会议)
成都
英文
433-436
2009-08-24(万方平台首次上网日期,不代表论文的发表时间)