Outgassing of Materials Used for Thin Film Vacuum Packages
In this paper, outgassing of the thin film vacuum package is analyzed by integrated MEMS (Microelectromechanical system) resonator and RBS (Rutherford backscattering spectroscopy). Outgassing behavior of different thin film packaging materials is studied by exodiffusion experiments. It is demonstrated that a high temperature pre anneal will greatly reduce the outgassing but can not eliminate it.
Q. Li J.F.L. Goosen J.T.M. van Beek F. van Keulen G.Q. Zhang
Materials innovation institute, Mekelweg 2, 2600GA, Delft, The Netherlands Department of Precision a Department of Precision and Microsystems Engineering, Delft University of Technology,Mekelweg 2, 262 NXP Semiconductors, Eindhoven, The Netherlands Department of Precision and Microsystems Engineering, Delft University of Technology, Mekelweg 2, 26
国际会议
北京
英文
802-806
2009-08-10(万方平台首次上网日期,不代表论文的发表时间)