A New Classic Camera Calibration Method Based on Coplanar Points
As a necessary step of 3D reconstruction, and a premise and base for computer vision obtaining the spatial information of 3D objects, research on the camera calibration methods has great important significance of theoretical study and practical value. This paper introduces a new simply, flexible and more accurate classic camera calibration method based on coplanar points. This method only requires a coplanar target and without camera motion. We use step-by-step calibration thinking, and first calibrate the principal point, and then neglect the lens distortion and linearly solve all the parameters, when high accuracy is required, we can include Wengs lens distortion model and solve the distortion coefficient by nonlinear algorithm. The experiment of images proves the proposed method is accurate and effective.
Computer vision 3D reconstruction Camera calibration Coplanar points Lens distortion
Chen Xiaobo Tang Zhenhao Yang Yinghua Qin Shukai
College of Information Science and Engineering, Northeastern University, Shenyang, 110004
国际会议
2009年中国控制与决策会议(2009 Chinese Control and Decision Conference)
广西桂林
英文
4481-4485
2009-06-17(万方平台首次上网日期,不代表论文的发表时间)