Pretreatment of wastewater contained DMF by combined aerobic Fe-C micro-electrolysis and plural three-dimensional electrodes ozidation process
Membrane-making wastewater contains DMF, with high COD, toxicity and non-biodegradability. In this work, aerobic Fe-C micro-electrolysis and three-dimensional electrodes technology were applied for the pretreatment aiming to improve the biodegradability of the wastewater. It was found that the optional pretreatment conditions were pH 3 for Fe-C micro-electrolysis and pH 5 for the three -dimensional electrodes oxidation. As a result, the B/C increased to 0.38 from below 0.2, and the COD removal reached 99% by the combined process of pretreatment and biological contact reactor in a three-month test, and the effluent DMF concentration was below 10 mg/L.
N N-Dimethyl formamide (DMF) Fe-C micro-electrolysis three-dimensional electrodes ozidation biological contact ozidation
Dan HAN Youcai ZHAO Feiyu HONG
The State of Key Laboratory of Pollution Control and Resource Reuse Tongji University Shanghai,China School of Environmental Science and Municipal Engineering Lanzhou Jiaotong University Lanzhou,China
国际会议
北京
英文
1-4